126KV Transmission SF6 Circuit Breaker

The 126KV Transmission SF6 Circuit Breaker is a high-voltage switching device designed for 110kV-126kV transmission substations, power plants, and industrial power networks. It uses sulfur hexafluoride (SF6) gas arc-quenching technology to safely interrupt short-circuit currents and provide reliable protection for transformers, transmission lines, and electrical equipment.

Designed for outdoor high-voltage applications, this SF6 circuit breaker combines a sealed interrupter chamber, spring-operated mechanism, and high-performance insulation system to achieve long service life, low maintenance requirements, and stable operation under demanding environmental conditions.

Why Choose Our 126KV Transmission SF6 Circuit Breaker?

Feature Customer Benefits
SF6 Gas Arc Extinguishing Technology Fast arc extinction and excellent dielectric recovery for reliable fault interruption
Spring Stored-Energy Operating Mechanism Simple structure, high reliability, and reduced maintenance compared with hydraulic systems
Outdoor High Voltage Design Suitable for substations exposed to rain, dust, pollution, and temperature variations
High Mechanical Endurance More than 10,000 operating cycles for long-term grid applications
SCADA Monitoring Compatibility Real-time operating status feedback for intelligent substation management

Applications of 126KV SF6 Circuit Breaker

The 126KV Transmission SF6 Circuit Breaker is widely used in high-voltage power systems where safe switching and reliable fault protection are required.

  • 110kV and 126kV transmission substations
  • Power generation facilities
  • Grid modernization projects
  • Renewable energy transmission systems
  • Transformer and reactor protection
  • Industrial high-voltage power distribution networks

Key Technical Parameters

Parameter Specification
Rated Voltage 126 kV
Rated Current 2500A / 3150A optional
Rated Short-Circuit Breaking Current 40 kA
Rated Short-Circuit Making Current 100 kA peak
SF6 Gas Pressure (20°C) 0.6 MPa absolute pressure
Operating Mechanism Motor-driven spring stored-energy mechanism
Control Voltage DC 110V / 220V
Mechanical Endurance ≥10,000 operations
Creepage Distance ≥3150mm for heavy pollution environments

Performance Standards and Compliance

The breaker is designed according to international high-voltage switchgear requirements to ensure safe and reliable operation in transmission networks.

Test Item Performance Value Reference Standard
Power Frequency Withstand Voltage (1 min) 230 kV rms IEC 62271-100
Lightning Impulse Withstand Voltage 550 kV peak IEC 62271-100
Short-Time Withstand Current 40 kA / 3 seconds IEC 62271-100
Operating Sequence O–0.3s–CO–3min–CO IEC 62271-100
Break Time ≤60 ms IEC 62271-100
SF6 Leakage Rate ≤0.5% per year IEC 62271 requirements

Outdoor Environmental Adaptability

Item Standard Capability
Ambient Temperature -30°C to +40°C
Insulation Material Porcelain or composite insulator
Frame Material Corrosion-resistant galvanized steel structure
Installation Type Outdoor substation installation

Mechanical Structure and Dimensions

Description Value
Phase Distance 800 mm
Overall Height Approximately 2900 mm
Breaker Depth Approximately 1200 mm
Three-phase Weight Approximately 1800 kg

Intelligent Monitoring and Safety Features

The 126KV Transmission SF6 Circuit Breaker integrates multiple protection and monitoring functions to improve substation reliability. The SF6 density monitoring system provides temperature-compensated pressure indication, while auxiliary switches and position indicators deliver accurate operating status feedback for remote control systems.

The mechanism cabinet is equipped with anti-condensation heating to prevent moisture accumulation in humid environments. Optional digital monitoring components can support predictive maintenance by tracking breaker operation conditions and mechanical performance.

Factory Testing and Quality Control

Before delivery, every 126KV SF6 Circuit Breaker undergoes strict factory inspection to ensure stable performance and compliance with project requirements.

  • SF6 gas leakage test
  • Contact resistance measurement
  • Mechanical operation test
  • Opening and closing timing test
  • High-voltage withstand test
  • Insulation performance verification

FAQ

What is a 126KV Transmission SF6 Circuit Breaker?

A 126KV Transmission SF6 Circuit Breaker is a high-voltage protection device used in 110kV-126kV power transmission systems to interrupt fault currents and protect electrical equipment.

Why is SF6 gas used in high voltage circuit breakers?

SF6 gas provides excellent insulation strength and efficient arc extinguishing capability, allowing circuit breakers to interrupt high fault currents safely and reliably.

What applications require a 126KV SF6 circuit breaker?

It is commonly used in transmission substations, power plants, renewable energy projects, and industrial high-voltage networks.

Can this 126KV SF6 breaker be customized?

Yes. Rated current, control voltage, insulation configuration, altitude adaptation, and mechanical structure can be customized according to project requirements.

Get a Quote for 126KV Transmission SF6 Circuit Breaker

Looking for a reliable 126KV SF6 Circuit Breaker manufacturer or supplier for your transmission project? Contact us for technical specifications, customization solutions, and professional support for high-voltage substation applications.

Hot Products

  • Through Core Current Transformer

    Through Core Current Transformer

    Anqiang Power is a China manufacturer of through core current transformers. These current transformers are suitable for AC power systems with operating voltages below 35KV and are used for current measurement and circuit protection in power distribution equipment. We can customize through-core current transformers for voltage levels such as 10KV, 24KV, and 35KV according to customer requirements.
  • 24kV Outdoor Voltage Transformer

    24kV Outdoor Voltage Transformer

    Anqiang Power's independently developed 24KV outdoor voltage transformer is a single-phase, multi-winding, fully enclosed, outdoor epoxy resin cast transformer. It is suitable for use in power systems with a rated frequency of 50Hz or 60Hz and rated voltages of 6KV, 10KV, 17.5KV, and 24KV for voltage and energy measurement and relay protection purposes.
  • Indoor High Voltage Load Switch

    Indoor High Voltage Load Switch

    Anqiang Power is a China manufacturer of indoor high voltage load switches. Our load switches feature a unique transmission structure design, where the arc extinguishing chamber only withstands high voltage during the closing and opening moments. Therefore, they are compact and lightweight, allowing for simultaneous operation of both the isolation contact and the arc extinguishing contact.
  • Zero Sequence Current Transformer

    Zero Sequence Current Transformer

    Anqiang Power's independently developed Zero Sequence Current Transformer is suitable for power systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 0.5KV and below, for use in energy and voltage measurement and relay protection. It features high temperature resistance, good insulation performance, a compact size, and easy installation.
  • 12KV Outdoor Disconnecting Switch

    12KV Outdoor Disconnecting Switch

    Anqiang Power's 12KV outdoor disconnecting switch can be used for single-phase operation in three-phase line systems. It is a single-pole high-voltage switching device generally used in outdoor 12KV power grids to open and close circuits under no-load conditions. It features a fixed pull hook and self-locking mechanism, and is operated with an insulated hook stick for flexible and reliable operation.
  • Outdoor High Voltage Disconnect Switch

    Outdoor High Voltage Disconnect Switch

    Anqiang Power's Outdoor High Voltage Disconnect Switch are commonly used equipment in power systems. Their main function is to isolate voltage during equipment or line maintenance to ensure safety. They cannot interrupt load current or short-circuit current and should be used in conjunction with circuit breakers. When shutting down power, the circuit breaker should be opened first, followed by the disconnect switch; when restoring power, the disconnect switch should be closed first, followed by the circuit breaker.

Send Inquiry

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.Privacy Policy