As distribution networks become increasingly automated, utilities require more than a conventional circuit breaker—they need intelligent equipment capable of detecting, analyzing, isolating, and restoring faults automatically. Our 33KV Vacuum Circuit Breaker With Recloser is specifically developed for smart distribution systems, combining high-performance vacuum interruption with advanced protection, fault analysis, and automatic reclosing technology. It is widely deployed in utility substations, overhead distribution feeders, renewable energy collection systems, mining facilities, industrial parks, and rural electrification projects where network reliability directly affects operational efficiency.
Built upon the proven interruption platform of our 33KV Vacuum Circuit Breaker, this intelligent solution integrates the automation capabilities of an Automatic Reclosing Circuit Breaker while sharing the rugged outdoor construction of our Outdoor Recloser Circuit Breaker. For utilities seeking a complete pole-mounted automation solution, it also complements the 33KV Outdoor Recloser Circuit Breaker product family. Together, these technologies help reduce outage duration, improve SAIDI/SAIFI performance, and lower maintenance costs across the distribution network.
Unlike conventional circuit breakers that simply disconnect faulted feeders, this equipment continuously monitors electrical parameters including phase current, voltage, power quality, and fault history. The intelligent controller automatically determines whether a disturbance is temporary or permanent before executing programmable reclosing sequences. Temporary faults caused by lightning, tree branches, wildlife, or contamination are restored automatically, while permanent faults remain isolated to minimize the impact on healthy sections of the network.
| Item | Specification |
|---|---|
| Rated Voltage | 33 kV |
| Maximum System Voltage | 36 kV |
| Rated Frequency | 50 Hz / 60 Hz |
| Rated Continuous Current | 630 A / 800 A / 1250 A |
| Rated Short Circuit Breaking Current | 20 kA / 25 kA |
| Rated Making Current | 50 kA / 63 kA Peak |
| Power Frequency Withstand Voltage | 70 kV (1 Minute) |
| Lightning Impulse Withstand Voltage | 170 kV BIL |
| Vacuum Interrupter Life | Maintenance-Free Sealed Type |
| Mechanical Life | 10,000 Operations |
| Electrical Life | 30 Full Fault Interruptions |
| Auto Reclosing Shots | 1–4 Programmable |
| Dead Time Setting | 0.2 s–300 s Adjustable |
| Protection Functions | 50/51, 50N/51N, 46, 49, 27, 59, 67, 79, 81 |
| Communication | IEC61850, DNP3, Modbus RTU/TCP, IEC60870-5-101/104 |
| Control Voltage | 24VDC / 48VDC /110VDC /220VDC |
| Operating Temperature | -40℃ to +55℃ |
| Humidity | 100% Condensing |
| Enclosure Protection | IP65 Control Cabinet / IP67 Main Tank |
| Applicable Standards | IEC 62271-100, IEC 62271-111, IEEE C37.60 |
| Comparison Item | Our 33KV Vacuum Circuit Breaker With Recloser | Typical Market Products |
|---|---|---|
| Fault Identification | Automatically distinguishes temporary and permanent faults | Basic overcurrent protection only |
| Automation Level | Smart feeder automation ready | Limited automation capability |
| Remote Management | Web, SCADA and engineering software supported | Requires additional gateway devices |
| Protection Functions | Comprehensive multifunction protection package | Basic protection configuration |
| Communication | Multiple international protocols available | Limited protocol compatibility |
| Maintenance | Vacuum interrupter requires minimal maintenance | More periodic inspection required |
| Environmental Performance | Oil-free & SF₆-free design available | Some products still use insulating gas |
| Project Customization | Flexible OEM & utility-specific configurations | Mostly standardized models |
| Engineering Support | Complete application engineering & commissioning assistance | Product-oriented support only |
A standard vacuum circuit breaker only interrupts fault current, while a recloser-equipped model automatically attempts to restore power after temporary faults through programmable reclosing sequences, improving feeder reliability and reducing outage duration.
It is ideal for utility distribution feeders, rural electrification projects, renewable energy substations, industrial distribution systems, mining operations, airports, railways, and smart grid automation projects.
Yes. The controller supports IEC 61850, DNP3, Modbus RTU/TCP, and IEC60870-5-101/104, allowing straightforward integration with most utility automation platforms.
Yes. Utilities can configure protection curves, reclosing attempts, dead times, lockout logic, coordination settings, communication parameters, and event recording functions according to their protection philosophy.
The sealed vacuum interrupter is maintenance-free. Periodic inspections mainly involve checking mechanical components, controller status, battery health, and communication functions, resulting in significantly lower maintenance costs than conventional switchgear.
Yes. We offer OEM manufacturing and customized solutions including protection relay selection, communication modules, CT/VT configurations, mounting structures, enclosure materials, operating mechanisms, and complete engineering documentation for EPC contractors and utility companies worldwide.
Our engineering team supports every stage of your distribution automation project—from product selection and protection coordination to schematic design, FAT testing, commissioning, and after-sales service. Every 33KV Vacuum Circuit Breaker With Recloser undergoes comprehensive factory testing before shipment, ensuring dependable performance, simplified installation, and long-term operational reliability for modern power distribution networks.